Pre-launch draft. Numbers await a welding inspector's check.

MIG settings for 24 gauge steel, by welder

Each maker's own chart settings for 24 gauge steel (about 0.6 mm, 0.024 in). Find your welder's row.

Solid wire with 75/25 gas

Welder.024 in.030 in.035 in
Handler 140switch 1 to 5 / wire dial1/301/25–
Handler 140EZvoltage knob / wire knob1/401.5/30–
Handler 210MVP120 V · switch 1 to 7 / wire speed4/255/15–
Handler 210MVP240 V · switch 1 to 7 / wire speed1/202/20–
Handler 210i120 V · volts / IPM16.2/12215.2/66–
Handler 210i240 V · volts / IPM16.2/12215.2/6615.2/59
Millermatic 211120 V · voltage knob / wire knob4.5/304/25–
Millermatic 211240 V · voltage knob / wire knob4/304.5/25–
Millermatic 211 PRO120 V or 240 V · volts / IPM15.0/14514.2/98–
Multimatic 215 PRO120 V or 240 V · volts / IPM15.0/14514.2/98–

Each cell is the maker's two settings for that wire size, in the units under the welder's name. A dash means the maker's chart gives nothing.

ER70S-6 solid wire with 75% argon / 25% CO2. The most common MIG setup for steel.

Chart has no 24 gauge column: Forney Easy Weld 140 MP. Open the welder's page and use the nearest thickness the maker printed.

Gasless flux-cored wire

Self-shielded flux-cored wire, no gas bottle.

No setting on the maker's chart at 24 gauge: Hobart Handler 140, Hobart Handler 140EZ, Hobart Handler 210MVP, Hobart Handler 210i, Miller Millermatic 211, Millermatic 211 PRO, Miller Multimatic 215 PRO. The chart has this thickness but leaves it blank for this wire, so we give no number.

Chart has no 24 gauge column: Forney Easy Weld 140 FC-i, Forney Easy Weld 140 MP. Open the welder's page and use the nearest thickness the maker printed.

Solid wire with 100% CO2

Welder.024 in.035 in
Handler 140switch 1 to 5 / wire dial1/25–
Handler 210i120 V · volts / IPM15.8/122–
Handler 210i240 V · volts / IPM15.8/12216.3/66

Each cell is the maker's two settings for that wire size, in the units under the welder's name. A dash means the maker's chart gives nothing.

ER70S-6 solid wire with straight CO2.

No setting on the maker's chart at 24 gauge: Hobart Handler 140EZ, Hobart Handler 210MVP, Miller Millermatic 211, Millermatic 211 PRO, Miller Multimatic 215 PRO. The chart has this thickness but leaves it blank for this wire, so we give no number.

What these charts tell you about 24 gauge steel

  • On the welders that show real numbers, the makers' charts for .030 in solid wire and 75/25 gas run from 14.2 to 15.2 volts and from 66 to 98 inches per minute.
  • Knob and switch numbers only mean something on that one welder. A "5" on a Forney is not a "5" on a Hobart, which is why each row is in its own units.

Thin sheet burns through easily. If holes open up, see burn-through.

Other thicknesses

Source

Every number comes from that welder's owner's manual. The manual, section and page are named on each welder's page, linked from its row.

Status: read from the manuals, waiting for a welding inspector's check. How we check numbers.