MIG settings for 22 gauge steel, by welder
Each maker's own chart settings for 22 gauge steel (about 0.8 mm, 0.030 in). Find your welder's row.
Solid wire with 75/25 gas
| Welder | .023 in | .024 in | .030 in | .035 in |
|---|---|---|---|---|
| Handler 140EZvoltage knob / wire knob | – | 1/40 | 2/30 | – |
| Handler 210MVP120 V · switch 1 to 7 / wire speed | – | 5/30 | 5/20 | – |
| Handler 210MVP240 V · switch 1 to 7 / wire speed | – | 2/25 | 2/25 | – |
| Handler 210i120 V · volts / IPM | – | 16.4/137 | 15.6/82 | – |
| Handler 210i240 V · volts / IPM | – | 16.4/137 | 15.6/82 | 15.3/63 |
| Easy Weld 140 MPvoltage knob / wire knob | 3/4 | – | 1/2 | – |
| Millermatic 211120 V or 240 V · voltage knob / wire knob | – | 4.5/45 | 4.5/30 | 4.5/30 |
| Millermatic 211 PRO120 V or 240 V · volts / IPM | – | 15.5/160 | 14.5/100 | 14.8/75 |
| Multimatic 215 PRO120 V or 240 V · volts / IPM | – | 15.5/160 | 14.5/100 | 14.8/75 |
Each cell is the maker's two settings for that wire size, in the units under the welder's name. A dash means the maker's chart gives nothing.
ER70S-6 solid wire with 75% argon / 25% CO2. The most common MIG setup for steel.
Chart has no 22 gauge column: Hobart Handler 140. Open the welder's page and use the nearest thickness the maker printed.
Gasless flux-cored wire
| Welder | .030 in |
|---|---|
| Easy Weld 140 FC-ivoltage knob / wire knob | 1/2 |
| Easy Weld 140 MPvoltage knob / wire knob | 1/1 |
Each cell is the maker's two settings for that wire size, in the units under the welder's name. A dash means the maker's chart gives nothing.
Self-shielded flux-cored wire, no gas bottle.
No setting on the maker's chart at 22 gauge: Hobart Handler 140EZ, Hobart Handler 210MVP, Hobart Handler 210i, Miller Millermatic 211, Millermatic 211 PRO, Miller Multimatic 215 PRO. The chart has this thickness but leaves it blank for this wire, so we give no number.
Chart has no 22 gauge column: Hobart Handler 140. Open the welder's page and use the nearest thickness the maker printed.
Solid wire with 100% CO2
| Welder | .024 in | .030 in | .035 in |
|---|---|---|---|
| Handler 140EZvoltage knob / wire knob | 2.5/45 | 4/35 | – |
| Handler 210i120 V · volts / IPM | 15.9/161 | – | – |
| Handler 210i240 V · volts / IPM | 15.9/161 | – | 16.5/74 |
| Millermatic 211120 V · voltage knob / wire knob | 6.5/40 | 5.5/25 | 5/30 |
| Millermatic 211240 V · voltage knob / wire knob | 6.5/40 | 5.5/25 | 5/25 |
| Millermatic 211 PRO120 V or 240 V · volts / IPM | 17.8/165 | 16.5/95 | 16.7/90 |
| Multimatic 215 PRO120 V or 240 V · volts / IPM | 17.8/165 | 16.5/95 | 16.7/90 |
Each cell is the maker's two settings for that wire size, in the units under the welder's name. A dash means the maker's chart gives nothing.
ER70S-6 solid wire with straight CO2.
No setting on the maker's chart at 22 gauge: Hobart Handler 210MVP. The chart has this thickness but leaves it blank for this wire, so we give no number.
Chart has no 22 gauge column: Hobart Handler 140. Open the welder's page and use the nearest thickness the maker printed.
What these charts tell you about 22 gauge steel
- On the welders that show real numbers, the makers' charts for .030 in solid wire and 75/25 gas run from 14.5 to 15.6 volts and from 82 to 100 inches per minute.
- Knob and switch numbers only mean something on that one welder. A "5" on a Forney is not a "5" on a Hobart, which is why each row is in its own units.
Thin sheet burns through easily. If holes open up, see burn-through.
Other thicknesses
Source
Every number comes from that welder's owner's manual. The manual, section and page are named on each welder's page, linked from its row.
Status: read from the manuals, waiting for a welding inspector's check. How we check numbers.