How thick can your welder weld?
The thinnest and thickest steel each maker's settings chart lists, in one pass. Find your welder's row.
| Welder | Solid wire, 75/25 gas | Gasless flux-cored |
|---|---|---|
| Handler 125120 V welder | 24 ga to 1/8 inthickest with .024, .030 in wire | 18 ga to 3/16 inthickest with .030, .035 in wire |
| Handler 140120 V welder | 24 ga to 3/16 in*thickest with .030, .035 in wire | 18 ga to 3/16 in*thickest with .030, .035 in wire |
| Handler 140EZ120 V welder | 24 ga to 1/8 in*thickest with .024, .030 in wire | 18 ga to 3/16 inthickest with .035 in wire |
| Handler 210MVP120 V power | 24 ga to 1/8 inthickest with .024, .030, .035 in wire | 18 ga to 1/4 inthickest with .035 in wire |
| Handler 210MVP240 V power | 24 ga to 1/4 in*thickest with .030, .035 in wire | 18 ga to 1/4 in*thickest with .030, .035, .045 in wire |
| Handler 210i120 V power | 24 ga to 3/16 inthickest with .024, .030, .035 in wire | 18 ga to 3/16 inthickest with .030, .035 in wire |
| Handler 210i240 V power | 24 ga to 3/8 inthickest with .030, .035 in wire | 18 ga to 3/8 inthickest with .035, .045 in wire |
| Easy Weld 140 FC-i120 V welder | not on chart | 22 ga to 1/4 inthickest with .030 in wire |
| Easy Weld 140 MP120 V welder | 22 ga to 1/4 inthickest with .030 in wire | 22 ga to 1/4 inthickest with .030 in wire |
| Millermatic 142120 V welder | 24 ga to 3/16 inthickest with .030 in wire | 18 ga to 3/16 inthickest with .030, .035 in wire |
| Millermatic 211120 V power | 24 ga to 3/16 inthickest with .024, .030, .035 in wire | 18 ga to 3/16 inthickest with .030, .035 in wire |
| Millermatic 211240 V power | 24 ga to 3/8 inthickest with .030, .035 in wire | 18 ga to 3/8 inthickest with .035, .045 in wire |
| Millermatic 211 PRO120 V power | 24 ga to 3/16 inthickest with .024, .030, .035 in wire | 18 ga to 3/16 inthickest with .030, .035 in wire |
| Millermatic 211 PRO240 V power | 24 ga to 3/8 inthickest with .030, .035 in wire | 18 ga to 3/8 inthickest with .035, .045 in wire |
| Multimatic 215 PRO120 V power | 24 ga to 3/16 inthickest with .024, .030, .035 in wire | 18 ga to 3/16 inthickest with .030, .035 in wire |
| Multimatic 215 PRO240 V power | 24 ga to 3/8 inthickest with .030, .035 in wire | 18 ga to 3/8 inthickest with .035, .045 in wire |
Thickest is in bold. "Not on chart" means the maker prints no setting for that wire on this welder. * The chart also lists thicker steel, but marks it as needing more than one pass.
What the charts show
- Hobart Handler 210MVP: with solid wire the chart stops at 1/8 in on 120 V and goes to 1/4 in on 240 V.
- Hobart Handler 210i: with solid wire the chart stops at 3/16 in on 120 V and goes to 3/8 in on 240 V.
- Miller Millermatic 211: with solid wire the chart stops at 3/16 in on 120 V and goes to 3/8 in on 240 V.
- Millermatic 211 PRO: with solid wire the chart stops at 3/16 in on 120 V and goes to 3/8 in on 240 V.
- Miller Multimatic 215 PRO: with solid wire the chart stops at 3/16 in on 120 V and goes to 3/8 in on 240 V.
- Flux-cored wire is listed for thicker steel than solid wire on: Hobart Handler 125; Hobart Handler 140EZ; Hobart Handler 210MVP on 120 V.
- For thin sheet, solid wire with gas goes thinner than flux-cored on most welders here. For example the Hobart Handler 125 chart starts at 24 ga with solid wire but 18 ga with flux-cored.
- This is what the settings chart covers, not a hard limit of the machine. Makers say thicker steel can be welded with joint preparation and more than one pass, but they give no single setting for it, so neither do we.
Get the setting for your thickness
Source
Worked out from the settings chart in each welder's owner's manual. The manual, section and page are named on each welder's page, linked from its row.
Status: read from the manuals, waiting for a welding inspector's check. How we check numbers.