Pre-launch draft. Numbers await a welding inspector's check.

Hobart Handler 210MVP settings chart

Power you plug into
Metal thickness
Hobart Handler 210MVPFrom the maker's chart

1/8 in (about 3.2 mm) steel, .030 in wire, on 120 V power

Voltage switch7 of 7
Wire speed setting50

On the maker's chart. A starting point: run a test bead on scrap first.

Gas: C25 (75% Ar / 25% CO2) at 20–30 CFH · Polarity: DCEP

Starting settings for the Hobart Handler 210MVP, read from Hobart's own chart in the owner's manual. Change the wire, gas or thickness and the card updates.

Setting it on the machine

  1. The voltage switch has seven numbered positions. On 230 V all seven are used; on 115 V only positions 4 to 7 are used.
  2. The switch must click into a position. Do not change it while you are welding. If it sits between positions the wire will not feed.
  3. The wire speed number on the chart is a starting value: fine-tune it while you weld.
  4. The welder comes with two plugs: the 115 V plug needs its own 20 A circuit, and the 230 V plug fits a NEMA 6-50R outlet.

From: Owner's manual sections 6-1 (controls, printed page 24), 5-10 to 5-13 (plugs) and 5-16.

The full chart

Hobart's chart, redrawn so it fits a phone. Thickness runs down the side and wire size across the top.

Steel: Solid ER70S-6, C25 (75% Ar / 25% CO2)

Gas: C25 (75% Ar / 25% CO2), 20–30 CFH · Polarity: DCEP

120 V power. Each cell: voltage switch / wire speed setting.
Thickness.024 in wire.030 in wire.035 in wire
24 ga0.6 mm4/255/15–
22 ga0.8 mm5/305/20–
18 ga1.2 mm6/406/256/20
16 ga1.5 mm6/456/306/25
1/8 in3.2 mm7/657/507/30
240 V power. Each cell: voltage switch / wire speed setting.
Thickness.024 in wire.030 in wire.035 in wire
24 ga0.6 mm1/202/20–
22 ga0.8 mm2/252/25–
18 ga1.2 mm3/403/252/20
16 ga1.5 mm3/503/303/20
1/8 in3.2 mm5/704/405/40
3/16 in4.8 mm6/805/506/40
1/4 in6.4 mm–6/606/45
3/8 in9.5 mm–6/70*7/50*
Steel: Solid ER70S-6, 100% CO2

Gas: 100% CO2, 20–30 CFH · Polarity: DCEP

120 V power. Each cell: voltage switch / wire speed setting.
Thickness.024 in wire.030 in wire.035 in wire
18 ga1.2 mm5/25––
16 ga1.5 mm6/356/256/20
1/8 in3.2 mm7/507/357/25
240 V power. Each cell: voltage switch / wire speed setting.
Thickness.024 in wire.030 in wire.035 in wire
18 ga1.2 mm3/303/303/20
16 ga1.5 mm4/404/303/25
1/8 in3.2 mm5/655/405/35
3/16 in4.8 mm5/706/406/35
1/4 in6.4 mm–6/507/40
3/8 in9.5 mm––7/45*
Stainless steel: Stainless steel, Tri-mix (90% He / 7.5% Ar / 2.5% CO2)

Gas: Tri-mix (90% He / 7.5% Ar / 2.5% CO2), 20–30 CFH · Polarity: DCEP

120 V power. Each cell: voltage switch / wire speed setting.
Thickness.024 in wire.030 in wire
18 ga1.2 mm5/305/20
16 ga1.5 mm6/306/25
1/8 in3.2 mm7/407/35
240 V power. Each cell: voltage switch / wire speed setting.
Thickness.024 in wire.030 in wire.035 in wire
18 ga1.2 mm3/353/253/20
16 ga1.5 mm4/404/304/25
1/8 in3.2 mm6/706/506/50
3/16 in4.8 mm–7/707/50
1/4 in6.4 mm––7/55
Steel: Flux-cored E71T-11, no gas

No shielding gas · Polarity: DCEN

120 V power. Each cell: voltage switch / wire speed setting.
Thickness.030 in wire.035 in wire
18 ga1.2 mm4/204/10
16 ga1.5 mm5/254/15
1/8 in3.2 mm7/406/20
3/16 in4.8 mm7/457/30
1/4 in6.4 mm–7/35
240 V power. Each cell: voltage switch / wire speed setting.
Thickness.030 in wire.035 in wire.045 in wire
18 ga1.2 mm1/201/15–
16 ga1.5 mm2/252/201/10
1/8 in3.2 mm4/454/354/15
3/16 in4.8 mm5/455/354/20
1/4 in6.4 mm5/506/455/25
3/8 in9.5 mm–7/50*6/30*
Aluminum (optional SpoolRunner 100 spool gun): 4043, 100% Argon

Gas: 100% Argon, 20–30 CFH · Polarity: DCEP

120 V power. Each cell: voltage switch / wire speed setting.
Thickness.030 in wire
18 ga1.2 mm4/60
16 ga1.5 mm5/70
1/8 in3.2 mm7/80
240 V power. Each cell: voltage switch / wire speed setting.
Thickness.030 in wire.035 in wire
18 ga1.2 mm2/60–
16 ga1.5 mm3/65–
1/8 in3.2 mm5/705/60
3/16 in4.8 mm6/856/75
1/4 in6.4 mm7/1007/90
Aluminum (optional SpoolRunner 100 spool gun): 5356, 100% Argon

Gas: 100% Argon, 20–30 CFH · Polarity: DCEP

120 V power. Each cell: voltage switch / wire speed setting.
Thickness.030 in wire
18 ga1.2 mm4/70
16 ga1.5 mm5/75
1/8 in3.2 mm7/90
240 V power. Each cell: voltage switch / wire speed setting.
Thickness.030 in wire.035 in wire
18 ga1.2 mm2/70–
16 ga1.5 mm3/75–
1/8 in3.2 mm5/905/80
3/16 in4.8 mm6/1006/90
1/4 in6.4 mm6/1007/100

What the manual says about this chart

  • Hobart's chart calls the two inputs 115 V and 230 V. They are the same household outlets this site calls 120 V and 240 V.
  • Cells are 'voltage switch position / wire speed setting'. The switch runs 1 to 7.
  • * in the chart means multiple passes may be needed, depending on the job and the joint (3/8 in column).
  • Chart says: settings are approximate; the wire speed listed is a starting value only; do not change the voltage switch while welding; suggested gas flow 20-30 cfh.
  • Aluminum settings are with the optional SpoolRunner 100 spool gun.
  • The chart labels its 1/8 in column '11 ga.' and its thin columns 24 ga (.024 in), 22 ga (.030 in), 18 ga (.048 in) and 16 ga (.060 in).
  • Rated output from the manual's specifications: 150 A at 23 V, 30% duty cycle on 230 V; 90 A at 19 V, 20% duty cycle on 115 V.

Source

Hobart Handler 210MVP owner's manual OM-260274F. Section 6-2, Weld Parameter Chart, printed page 24 (PDF page 26).

Read on 2026-11-26. Status: read from the manual, waiting for a welding inspector's check. We link to the manual and do not copy its pages. How we check numbers. Spotted a mistake? Tell us.

Other welders

Open the settings tool for any welder

Settings right but the weld still looks wrong?