Pre-launch draft. Numbers await a welding inspector's check.

Hobart Handler 140 settings chart

Metal thickness
Hobart Handler 140From the maker's chart

16 ga (about 1.5 mm) steel, .030 in wire

1234510100
Voltage switch2 of 5
Wire speed dial30

On the maker's chart. A starting point: run a test bead on scrap first.

No shielding gas · Polarity: DCEN

Starting settings for the Hobart Handler 140, read from Hobart's own chart in the owner's manual. Change the wire, gas or thickness and the card updates.

No longer sold new Retailers list the Handler 140EZ as its replacement.

The full chart

Hobart's chart, redrawn so it fits a phone. Thickness runs down the side and wire size across the top.

Steel: Flux core E71T-11, no gas

No shielding gas · Polarity: DCEN

Each cell: voltage switch / wire speed dial.
Thickness.030 in wire.035 in wire
18 ga1.2 mm1/30–
16 ga1.5 mm2/302/25
12 ga2.7 mm3/403/35
10 ga3.4 mm3/454/35
3/16 in4.8 mm4/505/35
1/4 in6.4 mm5/50*5/40*
Steel: Solid ER70S-6, C25 (75% Ar / 25% CO2)

Gas: C25 (75% Ar / 25% CO2) · Polarity: DCEP

Each cell: voltage switch / wire speed dial.
Thickness.024 in wire.030 in wire.035 in wire
24 ga0.6 mm1/301/25–
20 ga0.9 mm2/402/30–
18 ga1.2 mm2/502/352/30
16 ga1.5 mm3/503/353/30
12 ga2.7 mm4/554/404/35
10 ga3.4 mm–4/504/40
3/16 in4.8 mm–5/455/40
1/4 in6.4 mm–5/50*5/45*
Steel: Solid ER70S-6, 100% CO2

Gas: 100% CO2 · Polarity: DCEP

Each cell: voltage switch / wire speed dial.
Thickness.024 in wire.030 in wire.035 in wire
24 ga0.6 mm1/25––
20 ga0.9 mm2/352/30–
18 ga1.2 mm3/303/30–
16 ga1.5 mm3/403/353/25
12 ga2.7 mm4/504/304/30
10 ga3.4 mm5/504/354/35
3/16 in4.8 mm–5/355/30
1/4 in6.4 mm–5/40*5/35*
Stainless steel: Stainless, Tri-mix (90% He / 7.5% Ar / 2.5% CO2)

Gas: Tri-mix (90% He / 7.5% Ar / 2.5% CO2) · Polarity: DCEP

Each cell: voltage switch / wire speed dial.
Thickness.024 in wire.030 in wire
18 ga1.2 mm3/303/20
16 ga1.5 mm4/504/40
10 ga3.4 mm5/505/40
Stainless steel: Stainless, 98% Ar / 2% CO2

Gas: 98% Ar / 2% CO2 · Polarity: DCEP

Each cell: voltage switch / wire speed dial.
Thickness.024 in wire.030 in wire
18 ga1.2 mm1/451/40
16 ga1.5 mm2/602/50
10 ga3.4 mm4/704/60
Aluminum: 4043, 100% Argon

Gas: 100% Argon · Polarity: DCEP

Each cell: voltage switch / wire speed dial.
Thickness.030 in wire
16 ga1.5 mm3/90
12 ga2.7 mm5/90
Aluminum: 5356, 100% Argon

Gas: 100% Argon · Polarity: DCEP

Each cell: voltage switch / wire speed dial.
Thickness.030 in wire
16 ga1.5 mm2/100
12 ga2.7 mm4/100

* The maker marks 1/4 in as needing multiple passes.

What the manual says about this chart

  • Cells are 'voltage setting / wire feed setting'. Voltage settings on this chart run 1 to 5.
  • '*' in the chart means multiple passes required (1/4 in column).
  • Chart says: settings are approximate; wire speed listed is a starting value only; do not change the voltage switch while welding; suggested gas flow 20-30 cfh.
  • The voltage switch must click into one of its five positions, and must not be switched while welding (manual section 6-1).

Source

Hobart Handler 140 owner's manual OM-258267H (2020-07). Section 6-2, Weld Parameter Chart, printed page 19 (PDF page 21), figure 258 069-B, 'Welding Guide for 115 Volt Wire Welding Package'.

Read on 2026-11-26. Status: read from the manual, waiting for a welding inspector's check. We link to the manual and do not copy its pages. How we check numbers. Spotted a mistake? Tell us.

Other welders

Open the settings tool for any welder

Settings right but the weld still looks wrong?

Pinholes, spatter, holes in thin metal or a bead that sits on top each have their own fix. Fix a bad MIG weld