Pre-launch draft. Numbers await a welding inspector's check.

Hobart Handler 210i settings chart

Power you plug into
Metal thickness
Hobart Handler 210iFrom the maker's chart

1/8 in (about 3.2 mm) steel, .030 in wire, on 120 V power

Volts18.9 V
Wire speed295 IPM

On the maker's chart. A starting point: run a test bead on scrap first.

Gas: C25 (75% Ar / 25% CO2) at 25–45 CFH · Polarity: DCEP

Starting settings for the Hobart Handler 210i, read from Hobart's own chart in the owner's manual. Change the wire, gas or thickness and the card updates.

Setting it on the machine

  1. The left knob sets volts; the left display shows the number you set.
  2. The right knob sets wire speed; the right display shows it in inches per minute.
  3. While you weld, the left display switches to the actual arc volts and the right display to the welding amps, so don't be surprised when the right number changes. A few seconds after you stop, both go back to your settings.
  4. There is no automatic mode on this machine: you set both numbers from the chart.

From: Owner's manual section 5-1 (printed page 24).

The full chart

Hobart's chart, redrawn so it fits a phone. Thickness runs down the side and wire size across the top.

Steel: Solid ER70S-6, C25 (75% Ar / 25% CO2)

Gas: C25 (75% Ar / 25% CO2), 25–45 CFH · Polarity: DCEP

120 V power. Each cell: volts / wire speed in IPM.
Thickness.024 in wire.030 in wire.035 in wire
24 ga0.6 mm16.2/12215.2/66–
22 ga0.8 mm16.4/13715.6/82–
20 ga0.9 mm17.3/16516.2/10215.8/78
18 ga1.2 mm17.9/22816.7/11816.0/94
16 ga1.5 mm18.8/33417.4/16916.1/118
14 ga1.9 mm19.2/43717.6/24817.0/157
1/8 in3.2 mm20.0/61018.9/29517.9/185
3/16 in4.8 mm20.0/65019.0/30318.1/200
240 V power. Each cell: volts / wire speed in IPM.
Thickness.024 in wire.030 in wire.035 in wire
24 ga0.6 mm16.2/12215.2/6615.2/59
22 ga0.8 mm16.4/13715.6/8215.3/63
20 ga0.9 mm17.3/16516.2/10215.8/78
18 ga1.2 mm17.9/22816.7/11816.0/94
16 ga1.5 mm18.8/33417.4/16916.1/118
14 ga1.9 mm19.2/43717.6/24817.0/157
1/8 in3.2 mm20.0/61018.9/29518.3/220
3/16 in4.8 mm20.0/65019.0/30318.5/228
1/4 in6.4 mm–21.2/42120.8/303
5/16 in7.9 mm–22.2/51222.8/417
3/8 in9.5 mm–22.4/55123.1/437
Steel: Solid ER70S-6, C100 (100% CO2)

Gas: C100 (100% CO2), 15–30 CFH · Polarity: DCEP

120 V power. Each cell: volts / wire speed in IPM.
Thickness.024 in wire.030 in wire.035 in wire
24 ga0.6 mm15.8/122––
22 ga0.8 mm15.9/161––
20 ga0.9 mm15.9/18917.3/9016.6/82
18 ga1.2 mm19.5/29917.8/12617.0/98
16 ga1.5 mm20.6/39418.7/16517.7/126
14 ga1.9 mm21.0/52019.4/22418.3/169
1/8 in3.2 mm21.0/57519.5/25219.2/192
3/16 in4.8 mm–19.6/27320.0/200
240 V power. Each cell: volts / wire speed in IPM.
Thickness.024 in wire.030 in wire.035 in wire
24 ga0.6 mm15.8/122–16.3/66
22 ga0.8 mm15.9/161–16.5/74
20 ga0.9 mm15.9/18917.3/9016.6/82
18 ga1.2 mm19.5/29917.8/12617.0/98
16 ga1.5 mm20.6/39418.7/16517.7/126
14 ga1.9 mm21.0/52019.4/22418.3/169
1/8 in3.2 mm21.0/57519.8/28719.2/212
3/16 in4.8 mm21.0/63420.0/30720.0/228
1/4 in6.4 mm–22.7/40121.2/303
5/16 in7.9 mm–22.8/46422.8/362
3/8 in9.5 mm–23.0/48824.3/390
Stainless steel: Stainless 308L, C2 (98% Ar / 2% CO2)

Gas: C2 (98% Ar / 2% CO2), 25–45 CFH · Polarity: DCEP

120 V power. Each cell: volts / wire speed in IPM.
Thickness.024 in wire.030 in wire
18 ga1.2 mm16.8/24416.2/141
16 ga1.5 mm18.0/37817.2/228
14 ga1.9 mm19.0/46817.8/311
240 V power. Each cell: volts / wire speed in IPM.
Thickness.024 in wire.030 in wire.035 in wire
18 ga1.2 mm16.8/24416.2/14115.1/110
16 ga1.5 mm18.0/37817.2/22816.6/173
14 ga1.9 mm19.0/46817.8/31117.0/204
1/8 in3.2 mm21.3/65019.8/42118.0/267
3/16 in4.8 mm20.5/60020.1/45318.1/279
1/4 in6.4 mm–21.1/61420.1/405
Steel: Flux-cored E71T-11, no gas

No shielding gas · Polarity: DCEN

120 V power. Each cell: volts / wire speed in IPM.
Thickness.030 in wire.035 in wire
18 ga1.2 mm15.0/7815.0/63
16 ga1.5 mm16.5/18516.3/94
14 ga1.9 mm18.0/26016.3/149
1/8 in3.2 mm20.3/31118.8/200
3/16 in4.8 mm20.7/35820.1/203
240 V power. Each cell: volts / wire speed in IPM.
Thickness.030 in wire.035 in wire.045 in wire
18 ga1.2 mm15.0/7815.0/63–
16 ga1.5 mm16.5/18516.3/94–
14 ga1.9 mm18.0/26016.3/14916.5/78
1/8 in3.2 mm20.7/40718.5/21618.5/110
3/16 in4.8 mm21.2/42320.1/25220.0/122
1/4 in6.4 mm23.5/60622.0/33821.5/173
5/16 in7.9 mm–23.3/46422.0/189
3/8 in9.5 mm–23.5/50023.0/228
Aluminum (optional SpoolRunner): ER4043, 100% Argon

Gas: 100% Argon, 35–45 CFH · Polarity: DCEP

120 V power. Each cell: volts / wire speed in IPM.
Thickness.030 in wire
18 ga1.2 mm13.8/267
16 ga1.5 mm14.1/295
14 ga1.9 mm14.7/346
1/8 in3.2 mm18.5/417
240 V power. Each cell: volts / wire speed in IPM.
Thickness.030 in wire.035 in wire
18 ga1.2 mm13.8/26713.2/189
16 ga1.5 mm14.1/29513.6/220
14 ga1.9 mm14.7/34614.0/287
1/8 in3.2 mm18.5/41718.4/350
3/16 in4.8 mm20.8/42521.1/338
1/4 in6.4 mm21.8/53922.2/437
Aluminum (optional SpoolRunner): ER5356, 100% Argon

Gas: 100% Argon, 35–45 CFH · Polarity: DCEP

120 V power. Each cell: volts / wire speed in IPM.
Thickness.030 in wire.035 in wire
18 ga1.2 mm12.7/240–
16 ga1.5 mm13.3/295–
14 ga1.9 mm14.9/41715.0/346
1/8 in3.2 mm19.8/57518.8/429
240 V power. Each cell: volts / wire speed in IPM.
Thickness.030 in wire.035 in wire
18 ga1.2 mm12.7/240–
16 ga1.5 mm13.3/295–
14 ga1.9 mm14.9/41715.0/346
1/8 in3.2 mm19.8/57519.0/470
3/16 in4.8 mm21.5/62219.3/437
1/4 in6.4 mm22.0/65021.4/606

What the manual says about this chart

  • Cells are 'volts / wire speed in IPM'. Blocks for 120 V and 240 V input.

Source

Hobart Handler 210i owner's manual OM-402572. Section 5-3, Welding Parameter Chart, printed page 25 (PDF page 29).

Read on 2026-11-26. Status: read from the manual, waiting for a welding inspector's check. We link to the manual and do not copy its pages. How we check numbers. Spotted a mistake? Tell us.

Other welders

Open the settings tool for any welder

Settings right but the weld still looks wrong?

Pinholes, spatter, holes in thin metal or a bead that sits on top each have their own fix. Fix a bad MIG weld