Forney Easy Weld 140 MP settings chart

Metal thickness
Forney Easy Weld 140 MPFrom the maker's chart

1/8 in (about 3.2 mm) mild steel, .030 in wire

Left knob (voltage)6
Right knob (wire feed)7

On the maker's chart. A starting point: run a test bead on scrap first.

Gas: 75% Ar + 25% CO2

Starting settings for the Forney Easy Weld 140 MP, read from Forney's own chart in the owner's manual. Change the wire, gas or thickness and the card updates.

Setting it on the machine

  1. Set the selector switch to the top position for MIG or flux-cored welding.
  2. The left knob sets voltage and the right knob sets wire feed speed. Both run from 1 to 10. The numbers are a scale, not real volts or inches per minute.
  3. Polarity is set with the jumper lead: for gasless flux-cored wire, jumper to negative and ground clamp to positive; for MIG with gas, jumper to positive and ground clamp to negative.
  4. In stick and TIG the left knob sets the amps on the same 1 to 10 scale, and the right knob does nothing.

From: Owner's manual page 12 (front panel controls) and page 19 (MIG setup).

The full chart

Forney's chart, redrawn so it fits a phone. Thickness runs down the side and wire size across the top.

Mild steel: Solid ER70S-6, 75% Ar + 25% CO2

Gas: 75% Ar + 25% CO2

Each cell: left knob (voltage) / right knob (wire feed).
Thickness.023 in wire.030 in wire
22 ga0.8 mm3/41/2
16 ga1.5 mm8/93/4
1/8 in3.2 mm10/106/7
3/16 in4.8 mm10/108/9
1/4 in6.4 mm–10/9
Mild steel: Flux-cored E71T-GS, no gas

No shielding gas

Each cell: left knob (voltage) / right knob (wire feed).
Thickness.030 in wire
22 ga0.8 mm1/1
16 ga1.5 mm3/3
1/8 in3.2 mm5/5
3/16 in4.8 mm7/7
1/4 in6.4 mm10/10
Stainless steel: ER308L, 90% He + 7.5% Ar + 2.5% CO2

Gas: 90% He + 7.5% Ar + 2.5% CO2

Each cell: left knob (voltage) / right knob (wire feed).
Thickness.030 in wire
22 ga0.8 mm7/6
16 ga1.5 mm8/9
1/8 in3.2 mm10/10

Stick welding

Set the process switch to the middle position and remove the polarity jumper. The left knob sets the amperage. Check the electrode packaging for polarity.

Left knob setting, by electrode diameter. Source: '140 MP Stick Set-Up Chart', manual page 20.
Electrode1/16 in (1.6 mm)5/64 in (2 mm)3/32 in (2.4 mm)1/8 in (3 mm)
Mild steel, E6010––6–910
Mild steel, E6011 / E6013 / E60142–55–86–910
Mild steel, E7018––8–1010
Stainless steel, E308L––7–108–10

TIG welding (lift arc)

Set the process switch to the bottom position. 100% argon, 1/16 in (1.6 mm) tungsten; the manual recommends lanthanated tungsten, 1/16 or 3/32 in maximum. The left knob sets the amperage. Gas flow is controlled by hand at the torch.

Left knob setting, by metal thickness. Source: '140 MP TIG Set-Up Chart', manual page 21.
Metal22 gauge16 gauge1/8 in (3 mm)3/16 in (5 mm)
Mild steel1–34–66–88–10

What the manual says about this chart

  • Cells are 'left knob / right knob' (voltage / wire feed).
  • Chart states: CANNOT WELD ALUMINUM. Manual: 'This machine is not an appropriate power source for welding aluminum.'

Source

Forney Easy Weld 140 MP (item 271) manual. '140 MP MIG Set-Up Chart', page 19; stick chart, page 20; TIG chart, page 21.

Read on 2026-11-26. Status: read from the manual, waiting for a welding inspector's check. We link to the manual and do not copy its pages. How we check numbers. Spotted a mistake? Tell us.

Other welders

Open the settings tool for any welder

Settings right but the weld still looks wrong?

Pinholes, spatter, holes in thin metal or a bead that sits on top each have their own fix. Fix a bad MIG weld