Hobart Handler 140EZ settings chart
1/8 in (about 3.2 mm) steel, .030 in wire
On the maker's chart. A starting point: run a test bead on scrap first.
Gas: Argon 75% / CO2 25% at 25–45 cfh · Polarity: DCEP
Starting settings for the Hobart Handler 140EZ, read from Hobart's own chart in the owner's manual. Change the wire, gas or thickness and the card updates.
Newer model Retailers list it as the replacement for the Handler 140. The two have different controls and different charts.
EZ Mode or manual?
In EZ Mode the owner sets thickness on the left knob and wire diameter on the right; the machine sets the rest. Manual settings come from the chart below.
The numbers on this page are the manual settings from the chart. Use them when you want to set both knobs yourself.
The full chart
Hobart's chart, redrawn so it fits a phone. Thickness runs down the side and wire size across the top.
Steel: Solid ER70S-6, Argon 75% / CO2 25%
Gas: Argon 75% / CO2 25%, 25–45 cfh · Polarity: DCEP
| Thickness | .024 in wire | .030 in wire |
|---|---|---|
| 24 ga0.6 mm | 1/40 | 1.5/30 |
| 22 ga0.8 mm | 1/40 | 2/30 |
| 20 ga0.9 mm | 2/45 | 3/35 |
| 18 ga1.2 mm | 3/55 | 3.5/40 |
| 16 ga1.5 mm | 4/70 | 5/50 |
| 14 ga1.9 mm | 5/80 | 6/60 |
| 1/8 in3.2 mm | 9/100 | 10/65 |
| 3/16 in4.8 mm | multi-pass | multi-pass |
Steel: Solid ER70S-6, CO2 100%
Gas: CO2 100%, 15–35 cfh · Polarity: DCEP
| Thickness | .024 in wire | .030 in wire |
|---|---|---|
| 22 ga0.8 mm | 2.5/45 | 4/35 |
| 20 ga0.9 mm | 3/45 | 4.5/35 |
| 18 ga1.2 mm | 3.5/55 | 4.5/40 |
| 16 ga1.5 mm | 4/65 | 5/45 |
| 14 ga1.9 mm | 5/80 | 7/50 |
| 1/8 in3.2 mm | 9/100 | 10/60 |
| 3/16 in4.8 mm | multi-pass | multi-pass |
Steel: Flux-cored, no gas
No shielding gas · Polarity: DCEN
| Thickness | .030 in wire | .035 in wire |
|---|---|---|
| 18 ga1.2 mm | 2/30 | 2/25 |
| 16 ga1.5 mm | 3/35 | 3/30 |
| 14 ga1.9 mm | 4/40 | 4/35 |
| 1/8 in3.2 mm | 10/65 | 10/45 |
| 3/16 in4.8 mm | multi-pass | 10/50 |
Stainless steel: Stainless steel, Argon 98% / CO2 2%
Gas: Argon 98% / CO2 2%, 25–45 cfh · Polarity: DCEP
| Thickness | .024 in wire | .030 in wire |
|---|---|---|
| 22 ga0.8 mm | 1/50 | 2/45 |
| 20 ga0.9 mm | 1.5/50 | 2.5/45 |
| 18 ga1.2 mm | 2.5/60 | 3/50 |
| 16 ga1.5 mm | 3.5/70 | 4/60 |
| 14 ga1.9 mm | 5/80 | 5.5/75 |
| 1/8 in3.2 mm | 7/100 | 10/85 |
| 3/16 in4.8 mm | multi-pass | multi-pass |
Aluminum (with optional spool gun): 4043, 100% Argon
Gas: 100% Argon, 35–45 cfh · Polarity: DCEP
| Thickness | .030 in wire | .035 in wire |
|---|---|---|
| 18 ga1.2 mm | 1.5/75 | 2/65 |
| 16 ga1.5 mm | 2.5/80 | 2.5/70 |
| 14 ga1.9 mm | 4/85 | 4/80 |
What the manual says about this chart
- Cells are 'V / WFS': voltage knob setting / wire feed speed setting. Chart heading: 120 Volt.
- 'multi-pass' = the chart shows a dash with **: thicker materials can be welded using proper technique, joint preparation and multiple passes.
- Chart footnote *: EZ Mode is only for .035 in flux-cored wire (applies to the flux-cored row).
- Chart note: settings are approximate; adjust as required.
Source
Hobart Handler 140EZ owner's manual OM-296628. Section 6-5, Parameter Chart, printed page 26 (PDF page 30), figure 296626. Front panel: section 6-2, Using EZ Mode, printed page 24 (PDF page 28)..
Read on 2026-11-26. Status: read from the manual, waiting for a welding inspector's check. We link to the manual and do not copy its pages. How we check numbers. Spotted a mistake? Tell us.
Other welders
- Hobart Handler 140 settings chartStepped voltage switch
- Hobart Handler 210i settings chartDigital display
- Forney Easy Weld 140 FC-i settings chartTwo knobs, flux-core only
- Forney Easy Weld 140 MP settings chartTwo knobs, multi-process
- Millermatic 211 PRO settings chartDigital display
- Miller Multimatic 215 PRO settings chartDigital display, multi-process
Settings right but the weld still looks wrong?
Pinholes, spatter, holes in thin metal or a bead that sits on top each have their own fix. Fix a bad MIG weld