Hobart Handler 125 settings chart
1/8 in (about 3.2 mm) steel, .030 in wire
On the maker's chart. A starting point: run a test bead on scrap first.
No shielding gas · Polarity: DCEN
Starting settings for the Hobart Handler 125, read from Hobart's own chart in the owner's manual. Change the wire, gas or thickness and the card updates.
Setting it on the machine
- The voltage switch has four positions, 1 to 4. It must click into a position, and the chart says not to change it while welding.
- The wire feed number on the chart is a starting value only. Fine-tune it while you weld.
- For gasless flux-cored wire set the polarity to DCEN (electrode negative). For solid wire with gas set it to DCEP (electrode positive).
From: Owner's manual section 6-1 (controls, printed page 20) and the chart in section 6-3.
The full chart
Hobart's chart, redrawn so it fits a phone. Thickness runs down the side and wire size across the top.
Steel: Flux-cored E71T-11, no gas
No shielding gas · Polarity: DCEN
| Thickness | .030 in wire | .035 in wire |
|---|---|---|
| 18 ga1.2 mm | 1/10 | 1/10 |
| 16 ga1.5 mm | 1/15 | 1/15 |
| 14 ga1.9 mm | 2/15 | 2/20 |
| 12 ga2.7 mm | 2/25 | 3/20 |
| 1/8 in3.2 mm | 3/30 | 4/20 |
| 3/16 in4.8 mm | 4/35 | 4/25 |
Steel: Solid ER70S-6, C25 (75% Ar / 25% CO2)
Gas: C25 (75% Ar / 25% CO2), 20–30 CFH · Polarity: DCEP
| Thickness | .024 in wire | .030 in wire |
|---|---|---|
| 24 ga0.6 mm | 1/15 | 1/10 |
| 22 ga0.8 mm | 1/20 | 1/15 |
| 18 ga1.2 mm | 2/30 | 2/25 |
| 16 ga1.5 mm | 3/55 | 3/30 |
| 14 ga1.9 mm | 4/75 | 3/35 |
| 12 ga2.7 mm | 4/80 | 4/35 |
| 1/8 in3.2 mm | 4/90 | 4/40 |
Stainless steel: Stainless steel, Tri-mix (90% He / 7.5% Ar / 2.5% CO2)
Gas: Tri-mix (90% He / 7.5% Ar / 2.5% CO2), 20–30 CFH · Polarity: DCEP
| Thickness | .024 in wire |
|---|---|
| 18 ga1.2 mm | 3/30 |
| 16 ga1.5 mm | 3/35 |
| 14 ga1.9 mm | 4/45 |
| 12 ga2.7 mm | 4/50 |
What the manual says about this chart
- Cells are 'voltage switch position / wire feed setting'. The switch runs 1 to 4.
- Chart says: settings are approximate; thicker materials can be welded with proper technique, joint preparation and multiple passes; the wire feed setting listed is a starting value only; suggested gas flow 20-30 cfh.
- Solid wire needs shielding gas and DCEP polarity; flux-cored wire needs no gas and DCEN polarity.
- The chart has a 12 gauge (2.5 mm) column and no 20 gauge column.
- Rated output from the manual's specifications: 80 A at 18 V, 25% duty cycle, on a 120 V outlet. Amperage range 25 to 130 A.
Source
Hobart Handler 125 owner's manual OM-283007C. Section 6-3, Weld Parameter Chart, printed page 21 (PDF page 25).
Read on 2026-11-26. Status: read from the manual, waiting for a welding inspector's check. We link to the manual and do not copy its pages. How we check numbers. Spotted a mistake? Tell us.
Other welders
- Hobart Handler 140 settings chartStepped voltage switch
- Hobart Handler 140EZ settings chartTwo knobs with EZ Mode
- Hobart Handler 210MVP settings chartSeven-step voltage switch, 115/230 V
- Hobart Handler 210i settings chartDigital display
- Hobart Multi-Handler 200 settings chartDigital display, multi-process
- Forney Easy Weld 140 FC-i settings chartTwo knobs, flux-core only
Settings right but the weld still looks wrong?
Pinholes, spatter, holes in thin metal or a bead that sits on top each have their own fix. Fix a bad MIG weld