MIG settings for 5/16 inch steel, by welder
Each maker's own chart settings for 5/16 inch steel (about 7.9 mm, 0.313 in). Find your welder's row.
Solid wire with 75/25 gas
| Welder | .030 in | .035 in |
|---|---|---|
| Handler 210i240 V · volts / IPM | 22.2/512 | 22.8/417 |
| Millermatic 211 PRO240 V · volts / IPM | 21.5/470 | 21.5/420 |
| Multimatic 215 PRO240 V · volts / IPM | 21.5/470 | 21.5/420 |
Each cell is the maker's two settings for that wire size, in the units under the welder's name. A dash means the maker's chart gives nothing.
ER70S-6 solid wire with 75% argon / 25% CO2. The most common MIG setup for steel.
Chart has no 5/16 inch column: Hobart Handler 140, Hobart Handler 140EZ, Hobart Handler 210MVP, Forney Easy Weld 140 MP, Miller Millermatic 211. Open the welder's page and use the nearest thickness the maker printed.
Gasless flux-cored wire
| Welder | .035 in | .045 in |
|---|---|---|
| Handler 210i240 V · volts / IPM | 23.3/464 | 22.0/189 |
| Millermatic 211 PRO240 V · volts / IPM | 23.1/400 | 22.0/210 |
| Multimatic 215 PRO240 V · volts / IPM | 23.1/400 | 22.0/210 |
Each cell is the maker's two settings for that wire size, in the units under the welder's name. A dash means the maker's chart gives nothing.
Self-shielded flux-cored wire, no gas bottle.
Chart has no 5/16 inch column: Hobart Handler 140, Hobart Handler 140EZ, Hobart Handler 210MVP, Forney Easy Weld 140 FC-i, Forney Easy Weld 140 MP, Miller Millermatic 211. Open the welder's page and use the nearest thickness the maker printed.
Solid wire with 100% CO2
| Welder | .030 in | .035 in |
|---|---|---|
| Handler 210i240 V · volts / IPM | 22.8/464 | 22.8/362 |
| Millermatic 211 PRO240 V · volts / IPM | 24.0/425 | 24.0/375 |
| Multimatic 215 PRO240 V · volts / IPM | 24.0/425 | 24.0/375 |
Each cell is the maker's two settings for that wire size, in the units under the welder's name. A dash means the maker's chart gives nothing.
ER70S-6 solid wire with straight CO2.
Chart has no 5/16 inch column: Hobart Handler 140, Hobart Handler 140EZ, Hobart Handler 210MVP, Miller Millermatic 211. Open the welder's page and use the nearest thickness the maker printed.
What these charts tell you about 5/16 inch steel
- On the welders that show real numbers, the makers' charts for .030 in solid wire and 75/25 gas run from 21.5 to 22.2 volts and from 470 to 512 inches per minute.
- Hobart Handler 210i and Millermatic 211 PRO and Miller Multimatic 215 PRO list 5/16 inch steel on 240 V power only. On a 120 V outlet the chart is blank at this thickness.
- Knob and switch numbers only mean something on that one welder. A "5" on a Forney is not a "5" on a Hobart, which is why each row is in its own units.
On thick steel the usual problem is a weld that looks fine but has not gone deep enough. See incomplete penetration.
Other thicknesses
Source
Every number comes from that welder's owner's manual. The manual, section and page are named on each welder's page, linked from its row.
Status: read from the manuals, waiting for a welding inspector's check. How we check numbers.