MIG settings for 3/16 inch steel, by welder
Each maker's own chart settings for 3/16 inch steel (about 4.8 mm, 0.188 in). Find your welder's row.
Solid wire with 75/25 gas
| Welder | .023 in | .024 in | .030 in | .035 in |
|---|---|---|---|---|
| Handler 140switch 1 to 5 / wire dial | – | – | 5/45 | 5/40 |
| Handler 140EZvoltage knob / wire knob | – | multi-pass | multi-pass | – |
| Handler 210MVP240 V · switch 1 to 7 / wire speed | – | 6/80 | 5/50 | 6/40 |
| Handler 210i120 V · volts / IPM | – | 20.0/650 | 19.0/303 | 18.1/200 |
| Handler 210i240 V · volts / IPM | – | 20.0/650 | 19.0/303 | 18.5/228 |
| Easy Weld 140 MPvoltage knob / wire knob | 10/10 | – | 8/9 | – |
| Millermatic 211120 V · voltage knob / wire knob | – | 7.5/100 | 7/75 | 6/50 |
| Millermatic 211240 V · voltage knob / wire knob | – | 7/100 | 7/75 | 7/65 |
| Millermatic 211 PRO120 V · volts / IPM | – | 22.0/600 | 20.3/340 | 20.0/235 |
| Millermatic 211 PRO240 V · volts / IPM | – | 22.0/600 | 20.3/340 | 20.0/275 |
| Multimatic 215 PRO120 V · volts / IPM | – | 22.0/600 | 20.3/340 | 20.0/235 |
| Multimatic 215 PRO240 V · volts / IPM | – | 22.0/600 | 20.3/340 | 20.0/275 |
Each cell is the maker's two settings for that wire size, in the units under the welder's name. A dash means the maker's chart gives nothing.
ER70S-6 solid wire with 75% argon / 25% CO2. The most common MIG setup for steel.
Gasless flux-cored wire
| Welder | .030 in | .035 in | .045 in |
|---|---|---|---|
| Handler 140switch 1 to 5 / wire dial | 4/50 | 5/35 | – |
| Handler 140EZvoltage knob / wire knob | multi-pass | 10/50 | – |
| Handler 210MVP120 V · switch 1 to 7 / wire speed | 7/45 | 7/30 | – |
| Handler 210MVP240 V · switch 1 to 7 / wire speed | 5/45 | 5/35 | 4/20 |
| Handler 210i120 V · volts / IPM | 20.7/358 | 20.1/203 | – |
| Handler 210i240 V · volts / IPM | 21.2/423 | 20.1/252 | 20.0/122 |
| Easy Weld 140 FC-ivoltage knob / wire knob | 9/9 | – | – |
| Easy Weld 140 MPvoltage knob / wire knob | 7/7 | – | – |
| Millermatic 211120 V · voltage knob / wire knob | 7/50 | 7/40 | – |
| Millermatic 211240 V · voltage knob / wire knob | 7.5/65 | 8/65 | 7/40 |
| Millermatic 211 PRO120 V · volts / IPM | 18.3/300 | 18.3/250 | – |
| Millermatic 211 PRO240 V · volts / IPM | 22.2/380 | 22.2/325 | 21.0/175 |
| Multimatic 215 PRO120 V · volts / IPM | 18.3/300 | 18.3/250 | – |
| Multimatic 215 PRO240 V · volts / IPM | 22.2/380 | 22.2/325 | 21.0/175 |
Each cell is the maker's two settings for that wire size, in the units under the welder's name. A dash means the maker's chart gives nothing.
Self-shielded flux-cored wire, no gas bottle.
Solid wire with 100% CO2
| Welder | .024 in | .030 in | .035 in |
|---|---|---|---|
| Handler 140switch 1 to 5 / wire dial | – | 5/35 | 5/30 |
| Handler 140EZvoltage knob / wire knob | multi-pass | multi-pass | – |
| Handler 210MVP240 V · switch 1 to 7 / wire speed | 5/70 | 6/40 | 6/35 |
| Handler 210i120 V · volts / IPM | – | 19.6/273 | 20.0/200 |
| Handler 210i240 V · volts / IPM | 21.0/634 | 20.0/307 | 20.0/228 |
| Millermatic 211120 V · voltage knob / wire knob | 8/100 | 8/65 | 7/55 |
| Millermatic 211240 V · voltage knob / wire knob | 8.5/100 | 8/65 | 8/55 |
| Millermatic 211 PRO120 V · volts / IPM | 22.4/600 | 22.5/340 | 21.5/240 |
| Millermatic 211 PRO240 V · volts / IPM | 22.4/600 | 22.5/340 | 23.2/292 |
| Multimatic 215 PRO120 V · volts / IPM | 22.4/600 | 22.5/340 | 21.5/240 |
| Multimatic 215 PRO240 V · volts / IPM | 22.4/600 | 22.5/340 | 23.2/292 |
Each cell is the maker's two settings for that wire size, in the units under the welder's name. A dash means the maker's chart gives nothing.
ER70S-6 solid wire with straight CO2.
What these charts tell you about 3/16 inch steel
- On the welders that show real numbers, the makers' charts for .030 in solid wire and 75/25 gas run from 19.0 to 20.3 volts and from 303 to 340 inches per minute.
- Hobart Handler 210MVP lists 3/16 inch steel on 240 V power only. On a 120 V outlet the chart is blank at this thickness.
- Knob and switch numbers only mean something on that one welder. A "5" on a Forney is not a "5" on a Hobart, which is why each row is in its own units.
On thick steel the usual problem is a weld that looks fine but has not gone deep enough. See incomplete penetration.
Other thicknesses
Source
Every number comes from that welder's owner's manual. The manual, section and page are named on each welder's page, linked from its row.
Status: read from the manuals, waiting for a welding inspector's check. How we check numbers.