MIG settings for 18 gauge steel, by welder
Each maker's own chart settings for 18 gauge steel (about 1.2 mm, 0.048 in). Find your welder's row.
Solid wire with 75/25 gas
| Welder | .024 in | .030 in | .035 in |
|---|---|---|---|
| Handler 140switch 1 to 5 / wire dial | 2/50 | 2/35 | 2/30 |
| Handler 140EZvoltage knob / wire knob | 3/55 | 3.5/40 | – |
| Handler 210MVP120 V · switch 1 to 7 / wire speed | 6/40 | 6/25 | 6/20 |
| Handler 210MVP240 V · switch 1 to 7 / wire speed | 3/40 | 3/25 | 2/20 |
| Handler 210i120 V or 240 V · volts / IPM | 17.9/228 | 16.7/118 | 16.0/94 |
| Millermatic 211120 V or 240 V · voltage knob / wire knob | 5/50 | 5/40 | 4.5/40 |
| Millermatic 211 PRO120 V or 240 V · volts / IPM | 17.8/325 | 16.2/145 | 15.8/115 |
| Multimatic 215 PRO120 V or 240 V · volts / IPM | 17.8/325 | 16.2/145 | 15.8/115 |
Each cell is the maker's two settings for that wire size, in the units under the welder's name. A dash means the maker's chart gives nothing.
ER70S-6 solid wire with 75% argon / 25% CO2. The most common MIG setup for steel.
Chart has no 18 gauge column: Forney Easy Weld 140 MP. Open the welder's page and use the nearest thickness the maker printed.
Gasless flux-cored wire
| Welder | .030 in | .035 in |
|---|---|---|
| Handler 140switch 1 to 5 / wire dial | 1/30 | – |
| Handler 140EZvoltage knob / wire knob | 2/30 | 2/25 |
| Handler 210MVP120 V · switch 1 to 7 / wire speed | 4/20 | 4/10 |
| Handler 210MVP240 V · switch 1 to 7 / wire speed | 1/20 | 1/15 |
| Handler 210i120 V or 240 V · volts / IPM | 15.0/78 | 15.0/63 |
| Millermatic 211120 V or 240 V · voltage knob / wire knob | 4.5/25 | 4.5/25 |
| Millermatic 211 PRO120 V or 240 V · volts / IPM | 14.0/95 | 14.0/82 |
| Multimatic 215 PRO120 V or 240 V · volts / IPM | 14.0/95 | 14.0/82 |
Each cell is the maker's two settings for that wire size, in the units under the welder's name. A dash means the maker's chart gives nothing.
Self-shielded flux-cored wire, no gas bottle.
Chart has no 18 gauge column: Forney Easy Weld 140 FC-i, Forney Easy Weld 140 MP. Open the welder's page and use the nearest thickness the maker printed.
Solid wire with 100% CO2
| Welder | .024 in | .030 in | .035 in |
|---|---|---|---|
| Handler 140switch 1 to 5 / wire dial | 3/30 | 3/30 | – |
| Handler 140EZvoltage knob / wire knob | 3.5/55 | 4.5/40 | – |
| Handler 210MVP120 V · switch 1 to 7 / wire speed | 5/25 | – | – |
| Handler 210MVP240 V · switch 1 to 7 / wire speed | 3/30 | 3/30 | 3/20 |
| Handler 210i120 V or 240 V · volts / IPM | 19.5/299 | 17.8/126 | 17.0/98 |
| Millermatic 211120 V or 240 V · voltage knob / wire knob | 6.5/50 | 5.5/40 | 5.5/35 |
| Millermatic 211 PRO120 V or 240 V · volts / IPM | 19.2/250 | 17.5/145 | 18.5/120 |
| Multimatic 215 PRO120 V or 240 V · volts / IPM | 19.2/250 | 17.5/145 | 18.5/120 |
Each cell is the maker's two settings for that wire size, in the units under the welder's name. A dash means the maker's chart gives nothing.
ER70S-6 solid wire with straight CO2.
What these charts tell you about 18 gauge steel
- On the welders that show real numbers, the makers' charts for .030 in solid wire and 75/25 gas run from 16.2 to 16.7 volts and from 118 to 145 inches per minute.
- Knob and switch numbers only mean something on that one welder. A "5" on a Forney is not a "5" on a Hobart, which is why each row is in its own units.
Thin sheet burns through easily. If holes open up, see burn-through.
Other thicknesses
Source
Every number comes from that welder's owner's manual. The manual, section and page are named on each welder's page, linked from its row.
Status: read from the manuals, waiting for a welding inspector's check. How we check numbers.