Pre-launch draft. Numbers await a welding inspector's check.

MIG settings for 18 gauge steel, by welder

Each maker's own chart settings for 18 gauge steel (about 1.2 mm, 0.048 in). Find your welder's row.

Solid wire with 75/25 gas

Welder.024 in.030 in.035 in
Handler 140switch 1 to 5 / wire dial2/502/352/30
Handler 140EZvoltage knob / wire knob3/553.5/40–
Handler 210MVP120 V · switch 1 to 7 / wire speed6/406/256/20
Handler 210MVP240 V · switch 1 to 7 / wire speed3/403/252/20
Handler 210i120 V or 240 V · volts / IPM17.9/22816.7/11816.0/94
Millermatic 211120 V or 240 V · voltage knob / wire knob5/505/404.5/40
Millermatic 211 PRO120 V or 240 V · volts / IPM17.8/32516.2/14515.8/115
Multimatic 215 PRO120 V or 240 V · volts / IPM17.8/32516.2/14515.8/115

Each cell is the maker's two settings for that wire size, in the units under the welder's name. A dash means the maker's chart gives nothing.

ER70S-6 solid wire with 75% argon / 25% CO2. The most common MIG setup for steel.

Chart has no 18 gauge column: Forney Easy Weld 140 MP. Open the welder's page and use the nearest thickness the maker printed.

Gasless flux-cored wire

Welder.030 in.035 in
Handler 140switch 1 to 5 / wire dial1/30–
Handler 140EZvoltage knob / wire knob2/302/25
Handler 210MVP120 V · switch 1 to 7 / wire speed4/204/10
Handler 210MVP240 V · switch 1 to 7 / wire speed1/201/15
Handler 210i120 V or 240 V · volts / IPM15.0/7815.0/63
Millermatic 211120 V or 240 V · voltage knob / wire knob4.5/254.5/25
Millermatic 211 PRO120 V or 240 V · volts / IPM14.0/9514.0/82
Multimatic 215 PRO120 V or 240 V · volts / IPM14.0/9514.0/82

Each cell is the maker's two settings for that wire size, in the units under the welder's name. A dash means the maker's chart gives nothing.

Self-shielded flux-cored wire, no gas bottle.

Chart has no 18 gauge column: Forney Easy Weld 140 FC-i, Forney Easy Weld 140 MP. Open the welder's page and use the nearest thickness the maker printed.

Solid wire with 100% CO2

Welder.024 in.030 in.035 in
Handler 140switch 1 to 5 / wire dial3/303/30–
Handler 140EZvoltage knob / wire knob3.5/554.5/40–
Handler 210MVP120 V · switch 1 to 7 / wire speed5/25––
Handler 210MVP240 V · switch 1 to 7 / wire speed3/303/303/20
Handler 210i120 V or 240 V · volts / IPM19.5/29917.8/12617.0/98
Millermatic 211120 V or 240 V · voltage knob / wire knob6.5/505.5/405.5/35
Millermatic 211 PRO120 V or 240 V · volts / IPM19.2/25017.5/14518.5/120
Multimatic 215 PRO120 V or 240 V · volts / IPM19.2/25017.5/14518.5/120

Each cell is the maker's two settings for that wire size, in the units under the welder's name. A dash means the maker's chart gives nothing.

ER70S-6 solid wire with straight CO2.

What these charts tell you about 18 gauge steel

  • On the welders that show real numbers, the makers' charts for .030 in solid wire and 75/25 gas run from 16.2 to 16.7 volts and from 118 to 145 inches per minute.
  • Knob and switch numbers only mean something on that one welder. A "5" on a Forney is not a "5" on a Hobart, which is why each row is in its own units.

Thin sheet burns through easily. If holes open up, see burn-through.

Other thicknesses

Source

Every number comes from that welder's owner's manual. The manual, section and page are named on each welder's page, linked from its row.

Status: read from the manuals, waiting for a welding inspector's check. How we check numbers.