Pre-launch draft. Numbers await a welding inspector's check.

MIG settings for 14 gauge steel, by welder

Each maker's own chart settings for 14 gauge steel (about 1.9 mm, 0.075 in). Find your welder's row.

Solid wire with 75/25 gas

Welder.024 in.030 in.035 in
Handler 140EZvoltage knob / wire knob5/806/60–
Handler 210i120 V or 240 V · volts / IPM19.2/43717.6/24817.0/157
Millermatic 211120 V · voltage knob / wire knob6/705/505.5/50
Millermatic 211240 V · voltage knob / wire knob6/705.5/505.5/50
Millermatic 211 PRO120 V or 240 V · volts / IPM20.2/55017.8/26517.5/175
Multimatic 215 PRO120 V or 240 V · volts / IPM20.2/55017.8/26517.5/175

Each cell is the maker's two settings for that wire size, in the units under the welder's name. A dash means the maker's chart gives nothing.

ER70S-6 solid wire with 75% argon / 25% CO2. The most common MIG setup for steel.

Chart has no 14 gauge column: Hobart Handler 140, Hobart Handler 210MVP, Forney Easy Weld 140 MP. Open the welder's page and use the nearest thickness the maker printed.

Gasless flux-cored wire

Welder.030 in.035 in.045 in
Handler 140EZvoltage knob / wire knob4/404/35–
Handler 210i120 V · volts / IPM18.0/26016.3/149–
Handler 210i240 V · volts / IPM18.0/26016.3/14916.5/78
Millermatic 211120 V · voltage knob / wire knob5/405/30–
Millermatic 211240 V · voltage knob / wire knob5.5/405/305/25
Millermatic 211 PRO120 V · volts / IPM17.0/20017.8/192–
Millermatic 211 PRO240 V · volts / IPM17.0/20017.8/19215.8/85
Multimatic 215 PRO120 V · volts / IPM17.0/20017.8/192–
Multimatic 215 PRO240 V · volts / IPM17.0/20017.8/19215.8/85

Each cell is the maker's two settings for that wire size, in the units under the welder's name. A dash means the maker's chart gives nothing.

Self-shielded flux-cored wire, no gas bottle.

Chart has no 14 gauge column: Hobart Handler 140, Hobart Handler 210MVP, Forney Easy Weld 140 FC-i, Forney Easy Weld 140 MP. Open the welder's page and use the nearest thickness the maker printed.

Solid wire with 100% CO2

Welder.024 in.030 in.035 in
Handler 140EZvoltage knob / wire knob5/807/50–
Handler 210i120 V or 240 V · volts / IPM21.0/52019.4/22418.3/169
Millermatic 211120 V · voltage knob / wire knob7.5/856.5/456.5/45
Millermatic 211240 V · voltage knob / wire knob8/856.5/456.5/45
Millermatic 211 PRO120 V or 240 V · volts / IPM21.0/42520.0/21520.7/215
Multimatic 215 PRO120 V or 240 V · volts / IPM21.0/42520.0/21520.7/215

Each cell is the maker's two settings for that wire size, in the units under the welder's name. A dash means the maker's chart gives nothing.

ER70S-6 solid wire with straight CO2.

Chart has no 14 gauge column: Hobart Handler 140, Hobart Handler 210MVP. Open the welder's page and use the nearest thickness the maker printed.

What these charts tell you about 14 gauge steel

  • On the welders that show real numbers, the makers' charts for .030 in solid wire and 75/25 gas run from 17.6 to 17.8 volts and from 248 to 265 inches per minute.
  • Knob and switch numbers only mean something on that one welder. A "5" on a Forney is not a "5" on a Hobart, which is why each row is in its own units.

If the bead sits on top or spatters, Fix a bad MIG weld shows which way to turn each setting.

Other thicknesses

Source

Every number comes from that welder's owner's manual. The manual, section and page are named on each welder's page, linked from its row.

Status: read from the manuals, waiting for a welding inspector's check. How we check numbers.