Pre-launch draft. Numbers await a welding inspector's check.

Stick welding amperage chart

Electrode
Electrode diameter
Steel thickness
Stick (SMAW) on steelFrom welder charts

E6013 electrode, 1/8 in · 1/8 in (about 3.2 mm) steel

Amps to start from80–90 A

From 6 welders' charts. A starting point: run a test bead on scrap, then adjust.

Electrode maker's range for this rod size (Lincoln Fleetweld 37-RSP): AC 110–140 A · DC± 100–135 A

Pick your electrode, its diameter and the steel thickness. You get the amps printed on the stick charts of 6 welders from Hobart and Miller, and a straight answer when the charts leave that combination blank.

E6010 amperage chart

Listed on two of the six charts. Each cell is the amps the charts give; a range means the charts differ.

Steel thickness3/32 in rod1/8 in rod5/32 in rod
16 ga1.5 mm40––
14 ga1.9 mm5055–
1/8 in3.2 mm6070–80110–130
3/16 in4.8 mm7075–90130–140
1/4 in6.4 mm–90–100140–150
5/16 in7.9 mm–110160

E6011 amperage chart

Listed on all six charts. Each cell is the amps the charts give; a range means the charts differ.

Steel thickness3/32 in rod1/8 in rod5/32 in rod
16 ga1.5 mm40–50––
14 ga1.9 mm45–5060–65–
1/8 in3.2 mm6080120–130
3/16 in4.8 mm85–9090130–140
1/4 in6.4 mm–100140–150
5/16 in7.9 mm–110150–160
3/8 in9.5 mm––160

E6013 amperage chart

Listed on all six charts. Each cell is the amps the charts give; a range means the charts differ.

Steel thickness3/32 in rod1/8 in rod5/32 in rod
16 ga1.5 mm45–50––
14 ga1.9 mm55–6560–80–
1/8 in3.2 mm70–7580–90120
3/16 in4.8 mm9095–105130–140
1/4 in6.4 mm–115150–155
5/16 in7.9 mm–130155–165
3/8 in9.5 mm–155160–165

E7014 amperage chart

Listed on one of the six charts. Each cell is the amps the charts give; a range means the charts differ.

Steel thickness3/32 in rod1/8 in rod5/32 in rod
16 ga1.5 mm50––
14 ga1.9 mm70––
1/8 in3.2 mm85100115
3/16 in4.8 mm95110120
1/4 in6.4 mm–125145
5/16 in7.9 mm–135150
3/8 in9.5 mm–140155

E7018 amperage chart

Listed on all six charts. Each cell is the amps the charts give; a range means the charts differ.

Steel thickness3/32 in rod1/8 in rod5/32 in rod
16 ga1.5 mm60–65––
14 ga1.9 mm70––
1/8 in3.2 mm85–95105–120115–125
3/16 in4.8 mm95–100115–120120–145
1/4 in6.4 mm–120–125140–170
5/16 in7.9 mm–130145–180
3/8 in9.5 mm–135–140150–190

What the electrode maker says

Lincoln Electric prints a current range for each rod diameter. It is a range for the rod itself, not for one steel thickness, so it is wider than a welder's chart, which gives one number for one thickness.

Electrode3/32 in1/8 in5/32 in
E6010Lincoln Fleetweld 5P+DC± 50–85DC± 75–135DC± 100–175
E6011Lincoln Fleetweld 180-RSPAC 40–90
DC± 40–80
AC 65–120
DC± 60–110
AC 115–150
DC± 105–135
E6013Lincoln Fleetweld 37-RSPAC 75–115
DC± 70–105
AC 110–140
DC± 100–135
AC 160–200
DC± 145–180
E7014Lincoln Murex 7014AC 80–100
DC± 70–90
AC 110–150
DC± 100–140
AC 140–190
DC± 130–180
E7018Lincoln Excalibur 7018 MRDC+ 70–110
AC 80–120
DC+ 90–160
AC 100–160
DC+ 130–210
AC 140–210

Amps, as listed under "Typical operating procedures" on each Lincoln product page. Other brands of the same electrode class can differ: check the box.

What these charts show

  • Thin steel sits at the bottom of the rod's range, or under it. For 1/8 in steel with a 1/8 in E6013, the welder charts say 80–90 A, while Lincoln's range for that rod starts at 100 A on DC. The welder charts are set for the thickness; the rod's range is for the rod.
  • Bigger rod, more amps. On every chart here a 5/32 in electrode starts above a 1/8 in one, and a 3/32 in rod is the only size listed for 16 gauge steel.
  • Thicker steel, more amps. Each row climbs as the steel gets thicker. The charts stop where the maker stops recommending that rod size.
  • These are full-power numbers. They come from the 240 V charts (the Multimatic 255 has one chart for 208 V and up). On a 120 V outlet the dual-voltage welders list lower limits and no 5/32 in electrodes at all; their pages have the 120 V stick chart.
  • Not every chart goes by thickness. Forney's multi-process welders print a range of amps for each rod size, and the Forney Easy Weld 140 MP sets stick current on a 1 to 10 knob. Those charts are on each welder's own page, linked below, not in these tables.
  • Polarity. The Miller charts used here list DCEP for these electrodes. The Hobart chart says to check the polarity for your electrode. The electrode maker's box is the final word.

Each welder's own stick chart

MIG and flux-core settings tool · All welders · How we check numbers

Source

Hobart Multi-Handler 200 owner's manual OM-285922C. Welding Parameter Chart - 240V, section 5-13, Stick block.

Miller Multimatic 235 owner's manual OM-283935B. Section 7-1, Welding Parameters, printed pages 44 and 45 (PDF pages 48 and 49), Stick block.

Miller Multimatic 255 owner's manual OM-278174J. Section 6-19, Welding Parameter Chart - Stick And TIG, printed pages 55 and 56 (PDF pages 59 and 60), Stick block.

Miller Multimatic 215 owner's manual OM-272989E. Welding Parameter Chart - 240V, section 6-3 (printed page 32, PDF page 36), Stick block.

Miller Multimatic 215 PRO owner's manual OM-298868. Welding Parameter Chart, printed page 44 (PDF page 48), Stick block.

Miller Multimatic 220 AC/DC owner's manual OM-281426D. Welding Parameter Chart, 240V, section 6-7, Stick block.

Lincoln Electric Fleetweld 5P+, product page, typical operating procedures.

Lincoln Electric Fleetweld 180-RSP, product page, typical operating procedures.

Lincoln Electric Fleetweld 37-RSP, product page, typical operating procedures.

Lincoln Electric Murex 7014, product page, typical operating procedures.

Lincoln Electric Excalibur 7018 MR, product page, typical operating procedures.

Read on 2026-11-26. Status: read from the manuals and product pages, waiting for a welding inspector's check. The welder charts are the welder makers' starting amps for their own machines; the Lincoln ranges are that electrode maker's figures for its own rods. How we check numbers.