Forney 140 MPx settings chart

Metal thickness
Forney 140 MPxFrom the maker's chart

1/8 in (about 3.2 mm) mild steel, .030 in wire

Volts19.5–20 V
Wire speed190–200 IPM

On the maker's chart. A starting point: run a test bead on scrap first.

Gas: 75/25 (75% Ar / 25% CO2) · Polarity: DCEP

Starting settings for the Forney 140 MPx, read from Forney's own chart in the owner's manual. Change the wire, gas or thickness and the card updates.

Setting it on the machine

  1. Manual MIG: the left knob sets arc voltage and the right knob sets wire feed speed. The left display shows volts and the right display shows inches per minute. Start in the middle of the chart's range.
  2. TruSet is the automatic mode: the right knob sets the metal thickness and the left knob sets trim. The manual says the best performance is at a trim between -5 and +5. The chart on this page is for manual mode.
  3. Polarity is set with the jumper cable: for MIG with gas, jumper to positive and ground cable to negative; for flux-cored wire, jumper to negative and ground cable to positive.
  4. Stick and TIG: the left knob sets the amps; the right knob does nothing.

From: Owner's manual, controls section and page 26 (manual MIG set-up).

The full chart

Forney's chart, redrawn so it fits a phone. Thickness runs down the side and wire size across the top.

Mild steel: Solid wire, 75/25 (75% Ar / 25% CO2)

Gas: 75/25 (75% Ar / 25% CO2) · Polarity: DCEP

Each cell: volts / wire speed in IPM.
Thickness.024 in wire.030 in wire.035 in wire
20 ga0.9 mm14.5–15.5/165–17515.5–16.5/135–145–
18 ga1.2 mm15.5–16.5/175–18516–17/155–16516.5–17.5/135–145
16 ga1.5 mm16.5–17.5/185–19516.5–17.5/175–18516–17/155–165
14 ga1.9 mm17.5–18.5/180–20017.5–18.5/180–19017.5–18.5/175–185
12 ga2.7 mm18–19/190–20018–19/185–19518–19/185–195
1/8 in3.2 mm–19.5–20/190–20018.5–19.5/180–190
3/16 in4.8 mm––19–20/185–195
1/4 in6.4 mm––19.5–20/190–200

Mild steel: Flux-cored wire, no gas

No shielding gas · Polarity: DCEN

Each cell: volts / wire speed in IPM.
Thickness.030 in wire.035 in wire
20 ga0.9 mm14.5–15.5/125–135–
18 ga1.2 mm15.5–16.5/145–15514–15/125–135
16 ga1.5 mm16–17/165–17514.5–15.5/145–155
14 ga1.9 mm16.5–17.5/175–18515–16/165–175
12 ga2.7 mm17.5–18.5/185–19515.5–16.5/175–185
1/8 in3.2 mm18–19/190–20016–17/180–190
3/16 in4.8 mm18.5–19.5/195–20016.5–17.5/185–195
1/4 in6.4 mm–17–18/190–200

Stainless steel: Stainless wire, Tri-mix

Gas: Tri-mix · Polarity: DCEP

Each cell: volts / wire speed in IPM.
Thickness.030 in wire.035 in wire
20 ga0.9 mm16–17/155–16516.5–17.5/135–145
18 ga1.2 mm16.5–17.5/175–18517–18/155–165
16 ga1.5 mm17–18/185–19517.5–18.5/175–185
14 ga1.9 mm17.5–18.5/190–20018–19/185–195
12 ga2.7 mm–18.5–19.5/190–200

Stick welding

The left knob sets the amps. The chart gives a range of amps for each electrode diameter, not for each metal thickness. It tops out at 80 A.

Amps range, by electrode diameter. Source: '140 MPx Stick Setup Chart', page 28.
Electrode1/16 in (1.6 mm)5/64 in (2 mm)3/32 in (2.4 mm)1/8 in (3 mm)
Mild steel, E6011––25–7535–80
Mild steel, E601320–4030–5050–7060–80
Mild steel, E7014––70–8080
Mild steel, E7018––65–8080
Stainless steel, E308L25–3530–5055–7070–80

Stick welding amperage chart: these amps next to other makers' charts

TIG welding (DC)

Torch on the negative socket, ground cable on the positive socket; argon or argon/helium only. The left knob sets the amps. Gas flow is set by the valve on the torch: this welder has no gas solenoid for TIG. The manual says pure tungsten will not work with this welder.

Amps range, by metal thickness. Source: '140 MPx TIG Setup Chart', page 28.
Metal thicknessAmpsFiller rodTungsten
1/16 in50–801/16 in1/16 in
3/32 in80–1101/16 in1/16 in
1/8 in85–1203/32 in1/16 in

What the manual says about this chart

  • Cells are 'volts / wire feed speed'. The chart heads the two columns with a V symbol and a wire-feed symbol under the words 'Regulation Knob', and every cell is a range. In manual MIG the left display shows volts and the right display shows inches per minute, so this page shows V and IPM.
  • The chart prints the material, gas and wire diameter only. It does not name the wire class or the polarity; the manual's set-up steps give DCEP (jumper to positive) for MIG with gas and DCEN (jumper to negative) for flux-cored wire.
  • The chart has a 12 gauge column and no 22 or 24 gauge columns.
  • Under each gauge the chart also prints the thickness in inches and millimetres (20 gauge is .036 in, 0.9 mm).
  • Solid .035 wire at 16 gauge prints 16–17 volts, lower than the 16.5–17.5 volts it prints at 18 gauge. Recorded as printed.
  • The chart says the welder cannot weld aluminum.
  • The MIG chart matches the Forney 140 MIGx chart cell for cell. This welder adds stick and TIG, shown further down this page.
  • Maximum output from the manual: 140 A, on a 120 V supply.

Source

Forney 140 MPx (item 373) operating manual, rev. 06.29.2026. '140 MPx MIG Setup Chart', page 26; stick and TIG charts, page 28.

Read on 2026-11-26. Status: read from the manual, waiting for a welding inspector's check. We link to the manual and do not copy its pages. How we check numbers. Spotted a mistake? Tell us.

Other welders

Open the settings tool for any welder

Settings right but the weld still looks wrong?

Pinholes, spatter, holes in thin metal or a bead that sits on top each have their own fix. Fix a bad MIG weld