Hobart Handler 180 settings chart
1/8 in (about 3.2 mm) steel, .030 in wire
On the maker's chart. A starting point: run a test bead on scrap first.
Gas: C25 (75% Ar / 25% CO2) at 20–30 CFH · Polarity: DCEP
Starting settings for the Hobart Handler 180, read from Hobart's own chart in the owner's manual. Change the wire, gas or thickness and the card updates.
Setting it on the machine
- The voltage switch has four numbered positions, 1 to 4. The chart's first number is the switch position.
- Do not change the voltage switch while you are welding.
- The second number is the wire speed setting. It is a starting value: fine-tune it while you weld.
From: The notes printed on the chart itself (owner's manual section 6-3).
The full chart
Hobart's chart, redrawn so it fits a phone. Thickness runs down the side and wire size across the top.
Steel: Solid ER70S-6, C25 (75% Ar / 25% CO2)
Gas: C25 (75% Ar / 25% CO2), 20–30 CFH · Polarity: DCEP
| Thickness | .024 in wire | .030 in wire | .035 in wire |
|---|---|---|---|
| 24 ga0.6 mm | 1/30 | – | – |
| 20 ga0.9 mm | 1/35 | 1/30 | – |
| 18 ga1.2 mm | 1/45 | 1/40 | 1/25 |
| 16 ga1.5 mm | 2/50 | 2/40 | 2/30 |
| 1/8 in3.2 mm | 3/90 | 3/60 | 3/50 |
| 3/16 in4.8 mm | – | 3/70 | 3/60 |
| 1/4 in6.4 mm | – | – | 4/60* |
Steel: Solid ER70S-6, 100% CO2
Gas: 100% CO2, 20–30 CFH · Polarity: DCEP
| Thickness | .024 in wire | .030 in wire | .035 in wire |
|---|---|---|---|
| 18 ga1.2 mm | 2/30 | 2/20 | 2/10 |
| 16 ga1.5 mm | 2/35 | 2/30 | 2/20 |
| 1/8 in3.2 mm | 3/70 | 3/65 | 3/55 |
| 3/16 in4.8 mm | – | 4/40 | 4/30 |
| 1/4 in6.4 mm | – | – | 4/60* |
Stainless steel: Stainless steel, Tri-mix (90% He / 7.5% Ar / 2.5% CO2)
Gas: Tri-mix (90% He / 7.5% Ar / 2.5% CO2), 20–30 CFH · Polarity: DCEP
| Thickness | .024 in wire | .030 in wire | .035 in wire |
|---|---|---|---|
| 18 ga1.2 mm | 2/25 | 2/15 | – |
| 16 ga1.5 mm | 2/40 | 2/20 | 2/10 |
| 1/8 in3.2 mm | 3/50 | 2/40 | 2/30 |
| 3/16 in4.8 mm | – | 4/80 | 4/70 |
Steel: Flux-cored E71T-11, no gas
No shielding gas · Polarity: DCEN
| Thickness | .030 in wire | .035 in wire | .045 in wire |
|---|---|---|---|
| 18 ga1.2 mm | 1/25 | – | – |
| 16 ga1.5 mm | 1/30 | 1/20 | – |
| 1/8 in3.2 mm | 3/50 | 3/40 | 2/20 |
| 3/16 in4.8 mm | 3/60 | 3/50 | 3/40 |
| 1/4 in6.4 mm | 4/70* | 4/60 | 4/50 |
| 5/16 in7.9 mm | – | 4/75* | 4/60* |
Aluminum: Aluminum wire, 100% Argon
Gas: 100% Argon, 20–30 CFH · Polarity: DCEP
| Thickness | .030 in wire | .035 in wire |
|---|---|---|
| 16 ga1.5 mm | 1/100 | 1/95 |
| 1/8 in3.2 mm | 4/100 | 4/90 |
What the manual says about this chart
- This is the 2004 Handler 180, the 230 V model in the Handler 140 / 180 manual. Hobart no longer sells it. Hobart's chart calls the input 230 V; it is the same outlet this site calls 240 V.
- Cells are 'voltage switch position / wire speed setting'. The switch runs 1 to 4.
- * in the chart means multiple passes are required.
- Chart says: settings are approximate; the wire speed listed is a starting value only; do not change the voltage switch while welding; suggested gas flow 20-30 cfh; set the drive roll tension knob to 3 to start.
- Thin sheet: the only settings below 18 gauge are for solid wire with 75/25 gas (.024 wire at 24 and 20 gauge, .030 wire at 20 gauge).
- Aluminum: the chart marks these settings with a note that aluminum wire is soft, so it does not feed as well. It lists them at 16 gauge and 1/8 in only, with wire speeds of 90 to 100.
- The chart labels its 1/8 in column '11 ga.' There are no 22 or 14 gauge columns.