Pre-launch draft. Numbers await a welding inspector's check.

Hobart Handler 135 settings chart

Metal thickness
Hobart Handler 135From the maker's chart

1/8 in (about 3.2 mm) steel, .030 in wire

Voltage switch4 of 4
Wire speed setting50

On the maker's chart. A starting point: run a test bead on scrap first.

Gas: C25 (75% Ar / 25% CO2) at 20–30 CFH · Polarity: DCEP

Starting settings for the Hobart Handler 135, read from Hobart's own chart in the owner's manual. Change the wire, gas or thickness and the card updates.

Setting it on the machine

  1. The voltage switch has four numbered positions, 1 to 4. The chart's first number is the switch position.
  2. Do not change the voltage switch while you are welding.
  3. The second number is the wire speed setting. It is a starting value: fine-tune it while you weld.

From: The notes printed on the chart itself (owner's manual section 5-2).

The full chart

Hobart's chart, redrawn so it fits a phone. Thickness runs down the side and wire size across the top.

Steel: Solid ER70S-6, C25 (75% Ar / 25% CO2)

Gas: C25 (75% Ar / 25% CO2), 20–30 CFH · Polarity: DCEP

Each cell: voltage switch / wire speed setting.
Thickness.024 in wire.030 in wire
22 ga0.8 mm1/10–
18 ga1.2 mm1/202/10
16 ga1.5 mm2/303/30
1/8 in3.2 mm4/654/50

Steel: Solid ER70S-6, 100% CO2

Gas: 100% CO2, 20–30 CFH · Polarity: DCEP

Each cell: voltage switch / wire speed setting.
Thickness.024 in wire.030 in wire
18 ga1.2 mm2/103/10
16 ga1.5 mm2/154/10
1/8 in3.2 mm4/404/20

Stainless steel: Stainless steel, Tri-mix (90% He / 7.5% Ar / 2.5% CO2)

Gas: Tri-mix (90% He / 7.5% Ar / 2.5% CO2), 20–30 CFH · Polarity: DCEP

Each cell: voltage switch / wire speed setting.
Thickness.024 in wire.030 in wire
18 ga1.2 mm2/302/15
16 ga1.5 mm3/403/10
1/8 in3.2 mm4/504/30

Steel: Flux-cored E71T-11, no gas

No shielding gas · Polarity: DCEN

Each cell: voltage switch / wire speed setting.
Thickness.030 in wire.035 in wire
18 ga1.2 mm1/10–
16 ga1.5 mm1/201/10
1/8 in3.2 mm3/303/10
3/16 in4.8 mm4/404/30

Aluminum: Aluminum wire, 100% Argon

Gas: 100% Argon, 20–30 CFH · Polarity: DCEP

Each cell: voltage switch / wire speed setting.
Thickness.030 in wire
1/8 in3.2 mm4/90

What the manual says about this chart

  • This is the 2003 Handler 135, the 115 V model in the Handler 135 / 175 manual. Hobart no longer sells it. Hobart's chart calls the input 115 V; it is the same household outlet this site calls 120 V.
  • Cells are 'voltage switch position / wire speed setting'. The switch runs 1 to 4.
  • Chart says: settings are approximate, and thicker materials can be welded using proper technique, joint preparation and multiple passes; the wire speed listed is a starting value only; do not change the voltage switch while welding; suggested gas flow 20-30 cfh; set the drive roll tension knob to 3 to start.
  • The chart runs from 22 gauge to 3/16 in. Only flux-cored wire has a 3/16 in setting, and only .024 solid wire with 75/25 gas has a 22 gauge setting.
  • Aluminum: one setting only, .030 wire on 1/8 in (4/90). The chart notes that aluminum wire is relatively soft, so it does not feed as well.
  • At 1/8 in every solid wire is on switch position 4, the top of the switch.

Source

Hobart Handler 135 / 175 owner's manual OM-944 (196 639G, October 2003). Section 5-2, Weld Parameter Chart For 115 VAC Model, a two-page spread (PDF pages 24 and 25).

Read on 2026-11-26. Status: read from the manual, waiting for a welding inspector's check. We link to the manual and do not copy its pages. How we check numbers. Spotted a mistake? Tell us.

Other welders

Open the settings tool for any welder

Settings right but the weld still looks wrong?

Pinholes, spatter, holes in thin metal or a bead that sits on top each have their own fix. Fix a bad MIG weld