Hobart Handler 135 settings chart
1/8 in (about 3.2 mm) steel, .030 in wire
On the maker's chart. A starting point: run a test bead on scrap first.
Gas: C25 (75% Ar / 25% CO2) at 20–30 CFH · Polarity: DCEP
Starting settings for the Hobart Handler 135, read from Hobart's own chart in the owner's manual. Change the wire, gas or thickness and the card updates.
Setting it on the machine
- The voltage switch has four numbered positions, 1 to 4. The chart's first number is the switch position.
- Do not change the voltage switch while you are welding.
- The second number is the wire speed setting. It is a starting value: fine-tune it while you weld.
From: The notes printed on the chart itself (owner's manual section 5-2).
The full chart
Hobart's chart, redrawn so it fits a phone. Thickness runs down the side and wire size across the top.
Steel: Solid ER70S-6, C25 (75% Ar / 25% CO2)
Gas: C25 (75% Ar / 25% CO2), 20–30 CFH · Polarity: DCEP
| Thickness | .024 in wire | .030 in wire |
|---|---|---|
| 22 ga0.8 mm | 1/10 | – |
| 18 ga1.2 mm | 1/20 | 2/10 |
| 16 ga1.5 mm | 2/30 | 3/30 |
| 1/8 in3.2 mm | 4/65 | 4/50 |
Steel: Solid ER70S-6, 100% CO2
Gas: 100% CO2, 20–30 CFH · Polarity: DCEP
| Thickness | .024 in wire | .030 in wire |
|---|---|---|
| 18 ga1.2 mm | 2/10 | 3/10 |
| 16 ga1.5 mm | 2/15 | 4/10 |
| 1/8 in3.2 mm | 4/40 | 4/20 |
Stainless steel: Stainless steel, Tri-mix (90% He / 7.5% Ar / 2.5% CO2)
Gas: Tri-mix (90% He / 7.5% Ar / 2.5% CO2), 20–30 CFH · Polarity: DCEP
| Thickness | .024 in wire | .030 in wire |
|---|---|---|
| 18 ga1.2 mm | 2/30 | 2/15 |
| 16 ga1.5 mm | 3/40 | 3/10 |
| 1/8 in3.2 mm | 4/50 | 4/30 |
Steel: Flux-cored E71T-11, no gas
No shielding gas · Polarity: DCEN
| Thickness | .030 in wire | .035 in wire |
|---|---|---|
| 18 ga1.2 mm | 1/10 | – |
| 16 ga1.5 mm | 1/20 | 1/10 |
| 1/8 in3.2 mm | 3/30 | 3/10 |
| 3/16 in4.8 mm | 4/40 | 4/30 |
Aluminum: Aluminum wire, 100% Argon
Gas: 100% Argon, 20–30 CFH · Polarity: DCEP
| Thickness | .030 in wire |
|---|---|
| 1/8 in3.2 mm | 4/90 |
What the manual says about this chart
- This is the 2003 Handler 135, the 115 V model in the Handler 135 / 175 manual. Hobart no longer sells it. Hobart's chart calls the input 115 V; it is the same household outlet this site calls 120 V.
- Cells are 'voltage switch position / wire speed setting'. The switch runs 1 to 4.
- Chart says: settings are approximate, and thicker materials can be welded using proper technique, joint preparation and multiple passes; the wire speed listed is a starting value only; do not change the voltage switch while welding; suggested gas flow 20-30 cfh; set the drive roll tension knob to 3 to start.
- The chart runs from 22 gauge to 3/16 in. Only flux-cored wire has a 3/16 in setting, and only .024 solid wire with 75/25 gas has a 22 gauge setting.
- Aluminum: one setting only, .030 wire on 1/8 in (4/90). The chart notes that aluminum wire is relatively soft, so it does not feed as well.
- At 1/8 in every solid wire is on switch position 4, the top of the switch.
Source
Hobart Handler 135 / 175 owner's manual OM-944 (196 639G, October 2003). Section 5-2, Weld Parameter Chart For 115 VAC Model, a two-page spread (PDF pages 24 and 25).